HP Original Cartridges
(The "X" size won't fit the M601)
Reliable Remanufactured Cartridges
Error Message 98.00 for HP LaserJet M601, M602, M603 Series Printers.
HP Say:
98.00.01 Corrupt data in firmware volume
Description
Data corruption has occurred in the firmware volume.
Recommended action
Turn the product off, and then on. Use the Clean Disk item in the Preboot menu. Reload the firmware.
--HP Say:
98.00.02 Corrupt data in solutions volume
Description
Data corruption has occurred in the solutions volume.
Recommended action
Turn the product off, and then on. Use the Clean Disk item in the Preboot menu. Reload the firmware.
--HP Say:
98.00.03 Corrupt data in configuration volume
Description
Data corruption has occurred in the configuration volume.
Recommended action
Turn the product off, and then on. Use the Clean Disk item in the Preboot menu. Reload the firmware.
--HP Say:
98.00.04 Corrupt data in job data volume
Description
Data corruption has occurred in the job data volume.
Recommended action
Turn the product off, and then on. Rerun the file erase function.
--Copyright G & J Huskinson & MindMachine Associates Ltd 2013, 2015. Some pictures derived from HP User and Service guides. These technical pages do not constitute an offer for sale; just our knowledge at the time of writing. See the catalog. Sales pages on this Web site use cookies to store user information. We also use Google Analytics to track site useage patterns.